Description
The Lian Li 12 kW Hydro Cooling Kit is a self-contained liquid-cooling solution designed to support up to two Hydro ASIC miners or compatible air-to-hydro conversions. It integrates a high-power pump, reservoir, radiator and built-in 220 V power supply for simplified operation, while automatic fan control regulates coolant temperature according to system load. Next Level Corp provides local sales, installation guidance and long-term technical support.
| Manufacturer | Lian Li |
|---|---|
| Model | 12 kW Hydro Cooling Kit |
| Product type | Liquid cooling system for Hydro ASIC miners |
| Supported configuration | Up to 2 Hydro ASIC miners, depending on miner heat load and ambient conditions |
| Cooling capacity | Up to 12 kW (tested at 33 °C ambient) |
| Flow rate | Approximately 11 L/min |
| Pump / Fan speed | 0–6000 rpm with manual and automatic control |
| Control modes | Manual speed; Auto Mode 2/3 with temperature-based step curves; Auto Mode 4 with 35 °C target |
| Auto Mode 2 | <25 °C: 0% · 25–30 °C: 25% · 30–35 °C: 50% · 35–40 °C: 75% · >40–42 °C: 100% |
| Auto Mode 3 | <25 °C: 0% · 25–35 °C: 25% · 35–45 °C: 50% · 45–55 °C: 75% · >55–65 °C: 100% |
| Auto Mode 4 | Target temperature: 35 °C; fans automatically respond above the target |
| Noise level | Approximately 20–75 dB, depending on operating mode and fan speed |
| Tubing / Fittings | 12 mm ID silicone inlet/outlet tubing |
| Fluid capacity | Approximately 8 L |
| Recommended coolant | Pure water or suitable liquid-cooling coolant according to installation requirements |
| Power consumption (cooling unit) | Approximately 0.5 kW for pump and fans |
| Electrical input | Built-in 220 V PSU · C14 power inlet |
| Compatibility | Antminer, WhatsMiner, IceRiver, Avalon and Innosilicon Hydro miners; compatible air-to-hydro conversions with the appropriate cold plates and adapters |
| Dimensions (unit) | 750 × 220 × 580 mm |
| Package dimensions | 820 × 710 × 240 mm |
| Net weight | 21 kg |
| Gross weight | 24 kg |
| Measured coolant outlet temperature | Approximately 46.6 °C under the referenced 33 °C ambient test conditions |
Notes
- For dual-miner operation, lower ambient temperatures provide greater cooling headroom; high ambient temperatures reduce the system’s available cooling capacity.
- Use pure water or a suitable coolant according to the installation and maintenance requirements.
- Fully seat inlet and outlet hoses and remove trapped air from the loop to minimize bubbles and pump cavitation.
- Verify 12 mm ID tubing compatibility and the required adapters for the specific miner model before installation.
- Air-to-hydro conversions require the correct cold-plate kit and fittings for the miner being converted.
- Always perform a complete leak test before powering the miner.
- Monitor coolant temperature, flow and coolant condition during operation and perform periodic maintenance as required.
Your purchase includes (Next Level Corp)
- Compatibility guidance for your Hydro ASIC miner or air-to-hydro conversion.
- Installation and cooling-loop configuration guidance.
- Guidance for tubing, fittings, adapters and coolant setup.
- Pool and wallet configuration assistance when purchased together with mining equipment.
- Remote technical assistance for setup and operation.
- Lifetime 24/7 technical advice.
- Genuine spare parts and compatible cooling accessories available for sale.
- Local service and technical support in Bolivia.
- 1-year manufacturer’s warranty for the cooling unit; miner warranty remains subject to the corresponding miner manufacturer and purchase terms.
We ship worldwide by air. Tracking is provided 3 days after purchase.
Important Notice:
Cooling performance depends on miner heat output, ambient temperature, coolant flow, tubing configuration and installation conditions. Before connecting mining equipment, verify compatibility, electrical requirements, fittings and coolant-loop integrity, and perform a complete leak test.
Tags: Radiador, Enfriador de hydro, Refrigerante de hydro, Sistema de refrigeración líquida para minería, Kit de enfriamiento por agua, Fila enfriada por líquido.






Reviews
There are no reviews yet.